Customization: | Available |
---|---|
Application: | Construction, Overhead, Underground, Industrial, Power Station, Telecommunication, Computer, Car |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
CROSS-LINKED POLYETHYLENE INSULATED POWER CABLE
Cross-linked polyethylene power cable is a medium- and high-voltage power transmission cable that uses polyethylene treated by a cross-linking process as an insulation layer. Its core conductor is usually made of copper or aluminum. This cable uses chemical or physical methods to change the molecular structure of polyethylene from linear to a three-dimensional mesh, which significantly improves the heat resistance and mechanical strength of the material. It is mainly suitable for 1kV to 500kV power transmission and distribution systems.
The most prominent feature of this type of cable is its excellent heat resistance and electrical properties. Its insulation layer can remain stable under long-term operation at 90ºC and short-circuit conditions at 250ºC, and its dielectric loss is one order of magnitude lower than that of PVC cable. The cross-linked structure gives the cable excellent creep resistance and environmental stress cracking resistance, and it also has low smoke and halogen-free fireproof properties.
In the power system, cross-linked polyethylene cable has become the first choice for underground laying of urban power grids, especially for high-rise building power supply, subway tunnels, and other places with limited space. In new energy fields such as offshore wind power, its salt spray and radiation resistance meet special environmental requirements; in harsh working conditions such as chemical plants and nuclear power plants, its flame retardant and non-toxic properties significantly improve safety.
TECHNICAL PARAMETERS | |
Product Name | Cross-linked Polyethylene Insulated Power Cable |
Keywords | Power Cable |
Rated Voltage | 26/35kV |
Maximum Operating Temperature | 90 Celsius |
Maximum Short-Circuit Temperature | Not Exceeding 250 Celsius. |
Ambient Temperature For Installation | Not Less Than 0 Celsius |
OEM & ODM Custom | Accept |
LOGO Custom | Accept |
Sample | Accept |
Payment | T/T, L/C, Western Union |
MOQ | Low MOQ |
Type and name of cable | ||
Type | Name | Application |
YJV | Copper Core XLPE Insulated PVC Sheathed Power Cable | Indoor,tunnel,cable trench and other places, can not withstand externa mechanical forces.Single core cables are not allowed to be laid in magnetic management |
YJLV | Aluminum Core XLPE Insulated PVC Sheathed Power Cable | |
YJLY | Aluminum Core XLPE Insulated Polyethylene Sheathed Power Cable | |
YJV22 | Copper Core XLPE Insulated Steel Belt Armored PVC Sheathed Power Cable | Indoor,tunnel,cable trench or buried laying,can withstand certain mechanical external forces but can not withstand large tensian. |
YJLV22 | Aluminum Core XLPE Insulated Steel Belt Armored PVC Sheathed Power Cable | |
YV23 | Copper Core XLPE Insulated Steel Belt Armored Polyethylene Sheathed Power Cable | |
YJLV23 | Aluminum Core XLPE Insulated Steel Belt Armored Polyethylene Sheathed Power Cable | |
YV32 | Copper Core XLPE Insulated Fine Steel Wire Armored PVC Sheathed Power Cable | Indoor,tunnel,cable trench dredging or buried aying,etc,can withstand mechanical external force and certain tension |
YJLV32 | Aluminum Core XLPE Insulated Fine Steel Wire Armored PVC Sheathed Power Cable | |
YV33 | Copper Core XLPE Insulated Fine Steel Wire Armored Polyethylene Sheathed Power Cable | |
YJLV33 | Aluminum Core XLPE Insulated Fine Steel WireArmored Polyethylene Sheathed Power Cable |
U | Um | Uo | |
First class | Second class | ||
1 | 1.2 | 0.6 | 0.6 |
3 | 3.6 | 1.8 | 3.6 |
6 | 7.2 | 3.6 | 6 |
10 | 12 | 6 | 8.7 |
15 | 17.5 | 8.7 | 12 |
20 | 24 | 12 | 18 |
35 | 42 | 21 | 26 |
Nomina cros5 -sectiona area mm² |
nsulation thickness mm |
YJV YY YJLV YJLY | YIV22 YIV22 YLV23 YLV23 | YIV32 YIV32 YLV32 YILV32 | ||||||
Appres cwera damete mmn |
Calculated weight of cable |
Appres cweral daneter mm |
Calculated weight of cable |
Appraxs cral daTHter mm |
Calculated weight of cable |
|||||
YIV YJY |
YJLV YJLY |
YM22 YV22 |
YJLV23 YJLV23 |
YJLV23 YJLV23 |
YLV32 YLV32 |
|||||
1×50 | 10.5 | 37.3 | 1617 | 1328 | 42.3 | 2502 | 2213 | 44.3 | 2429 | 2140 |
1X70 | 10.5 | 38.9 | 1883 | 1464 | 44.1 | 2825 | 2406 | 45.9 | 2731 | 2312 |
1×95 | 10.5 | 40.8 | 2216 | 1636 | 45.8 | 3184 | 2604 | 47.8 | 3096 | 2516 |
1×120 | 10.5 | 42.0 | 2490 | 1762 | 47.4 | 3529 | 2801 | 49.0 | 3397 | 2669 |
1×150 | 10.5 | 43.8 | 2834 | 1935 | 49.0 | 3892 | 2993 | 510 | 3801 | 2902 |
1×185 | 10.5 | 45.4 | 3236 | 2115 | 50.8 | 4354 | 3233 | 53.8 | 4435 | 3314 |
1×240 | 10.5 | 48.0 | 3877 | 2409 | 53.6 | 5082 | 3614 | 56.6 | 5161 | 3693 |
1×300 | 10.5 | 50.5 | 4559 | 2714 | 56.1 | 5824 | 3979 | 59.1 | 5907 | 4062 |
1×400 | 10.5 | 53.2 | 5457 | 3092 | 59.0 | 6815 | 4450 | 62.0 | 6895 | 4530 |
1×500 | 10.5 | 56.7 | 6618 | 3582 | 62.5 | 8062 | 5026 | 65.5 | 8142 | 5106 |
1×630 | 10.5 | 60.6 | 8091 | 4182 | 66.6 | 9663 | 5754 | 69.6 | 9748 | 5839 |
1X800 | 10.5 | 64.9 | 9929 | 4926 | 71.1 | 11693 | 6636 | 74.1 | 11726 | 6723 |
1×1000 | 10.5 | 68.7 | 11799 | 5649 | 75.1 | 13640 | 7490 | 77.9 | 13703 | 7553 |
3X50 | 10.5 | 77.8 | 5550 | 4678 | 85.8 | 7814 | 6942 | 88.7 | 10721 | 9849 |
3X70 | 10.5 | 81.5 | 6466 | 5203 | 89.9 | 8869 | 7606 | 92.8 | 11874 | 10611 |
3X50 | 10.5 | 85.3 | 7608 | 5860 | 94.0 | 10051 | 8303 | 96.8 | 13204 | 11456 |
3×120 | 10.5 | 88.1 | 8503 | 6306 | 96.8 | 11021 | 8824 | 99.6 | 14296 | 12099 |
3×150 | 10.5 | 91.8 | 9596 | 6886 | 100.6 | 12226 | 9516 | 103.5 | 15602 | 12892 |
3X185 | 10.5 | 95.6 | 10966 | 7858 | 104.7 | 13719 | 10338 | 107.1 | 17092 | 13711 |
3X240 | 10.5 | 101.0 | 13036 | 8610 | 110.3 | 15899 | 11473 | 114.6 | 21058 | 16632 |
3×300 | 10.5 | 106.4 | 15185 | 9621 | 115.8 | 18246 | 12682 | 120.2 | 23649 | 18085 |
3×400 | 10.5 | 112.2 | 18054 | 10924 | 121.8 | 21279 | 14149 | 126.2 | 26909 | 19779 |
3×500 | 10.5 | 119.9 | 21809 | 1265S | 129.8 | 25245 | 16091 | 134.7 | 32164 | 23010 |
0.6/1kV single core cross-linked polyethylene insulated power cable | |||||||
Nominal Cross-sectiona area mm² |
Diameter of conductor mm |
YIV YJLV YIY YJLY | YJV22 YJLV22 YY23 YLV23 | ||||
Approx oweral diameter mm |
Cable weight,max Kg/km |
Approx overal diameter mm |
Cable weight,max Kg/km |
||||
YJV YJY |
YJLV YJLY |
YIV22 YJY23 |
YJLV22 YLY23 |
||||
1×1.5 | 0.7 | 5.7 | 35 | 26 | 9.1 | 124 | 115 |
1×2.5 | 0.7 | 6.1 | 47 | 31 | 9.5 | 141 | 126 |
1×4 | 0.7 | 6.6 | 63 | 38 | 9.9 | 163 | 139 |
1×6 | 0.7 | 7.1 | 84 | 47 | 10.4 | 191 | 155 |
1×10* | 0.7 | 8.5 | 128 | 67 | 11.8 | 255 | 194 |
1×16* | 0.7 | 9.5 | 184 | 89 | 12.8 | 324 | 229 |
1×25* | 0.9 | 11 | 276 | 126 | 14.4 | 438 | 289 |
1×35* | 0.9 | 12.2 | 367 | 160 | 15.5 | 545 | 338 |
1×50* | 1 | 13.2 | 494 | 202 | 16.6 | 687 | 394 |
1×70* | 1.1 | 15 | 698 | 276 | 18.4 | 915 | 496 |
1×95* | 1.1 | 16.9 | 947 | 361 | 20.1 | 1172 | 587 |
1×120* | 1.2 | 18.3 | 1175 | 475 | 21.5 | 1418 | 691 |
1×150* | 1.4 | 20.5 | 1451 | 543 | 23.5 | 1714 | 805 |
1×185* | 1.6 | 22.5 | 1799 | 669 | 25.5 | 2087 | 957 |
1×240* | 1.7 | 25.3 | 2335 | 854 | 28.1 | 2648 | 1167 |
1×300* | 1.8 | 28 | 2917 | 1052 | 30.8 | 3267 | 1402 |
1×400* | 2 | 31.1 | 3718 | 1346 | 33.9 | 4110 | 1736 |
1×500* | 2.2 | 35 | 4753 | 1692 | 39.8 | 5565 | 2504 |
1×630* | 2.4 | 39.5 | 6099 | 2160 | 44.1 | 7000 | 3062 |
1×800* | 2.6 | 44 | 7766 | 2718 | 48.8 | 8794 | 3747 |
Q1: Are you a factory or a trader?
A: We are a manufacturer integrating industry and trade. Welcome to visit our company.
Q2: Can I add my LOGO to the product?
A: We support on-demand customization, including LOGO customization, color customization, appearance size customization, etc.
Q3: What payment methods do you support?
A: We support T/T, Western Union, PayPal, cash, etc. The details can be negotiated.
Q4: What are your modes of transportation?
A: We usually choose the appropriate mode of transportation (sea, air, land) according to the conditions of the goods, or we can choose the mode of transportation according to your requirements.
Q5: How can I get an accurate quotation?
A: You can first send your specific demand information and product pictures, and we will customize a solution for you according to your needs and inform you of the specific price.